CAS # 288-32-4 IMIDAZOLE AR

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4190300, 4021360, Fax : + 91 129 4190333, 4027762
E-mail: info@blulux.com, blulux@rediffmail.com Website: www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: HARMFUL BY INGESTION, INHALATION/SKIN ABSORPTION. EXTREMELY DESTRUCTIVE TO TISSUE OF MUCOUS MEMBRANES, UPPER RESPIRATORY TRACT, EYES & SKIN. INHALATION MAY CAUSE EDEMA OF LARYNX & BRONCHI, CHEMICAL PNEUMONITIS & PULMONARY EDEMA.

Explanation of Carcinogenicity: NONE

Signs and Symptoms of Overexposure: IRRITATION, SPASM, INFLAMMATION, BURNING SENSATION, COUGHING, WHEEZING, LARYNGITIS, SHORTNESS OF BREATH, HEADACHE, NAUSEA, VOMITING.

Medical Conditions Aggravated by Overexposure: N/K

==============================================================================
FIRST AID
==============================================================================
EYES/SKIN: IMMEDIATELY FLUSH W/COPIOUS AMOUNTS OF WATER FOR 15 MINS. INHALATION: REMOVE TO FRESH AIR. GIVE CPR/OXYGEN IF NEEDED. INGESTION: IF CONSCIOUS, WASH MOUTH OUT W/WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: 293F

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: WATER SPRAY, CO2, DRY CHEMICAL POWDER, APPROPRIATE FOAM.

Fire Fighting Procedures: WEAR A SCBA & PROTECTIVE CLOTHING.

Unusal Fire/Explosion Hazard: EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: EVACUATE AREA. WEAR A SCBA, RUBBER BOOTS & HEAVY RUBBER GLOVES. SWEEP UP, PLACE IN A BAG & HOLD FOR WASTE DISPOSAL. AVOID RAISING DUST. VENTILATE AREA & WASH SITE AFTER MATERIAL PICKUP IS COMPLETE.
Neutralizing Agent: N/K

Waste Disposal Methods: DISSOLVE/MIX MATERIAL W/A COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN AFTERBURNER & SCRUBBER IAW/FEDERAL, STATE & LOCAL REGULATIONS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE IN A COOL DRY PLACE. KEEP TIGHTLY CLOSED. DON'T BREATHE DUST. DON'T GET IN EYES, ON SKIN/CLOTHING.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: WEAR A NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation: USE ONLY IN A CHEMICAL FUME HOOD.
Protective Gloves: RUBBER
Eye Protection: CHEMICAL SAFETY GOGGLES
Other Equipment: SAFETY SHOWER & EYE BATH
Work Hygenic Practices: SAFETY SHOWER & EYE BATH
Supplemental Safety & Health: N/K

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
492.8F
Melting/Freezing Point: 
192-195.8F
Decomposition Temp: 
N/K
Vapor Pressure: <1 Vapor Density: N/K
Specific Gravity: N/K
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: WHITE CHIPS
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: N/K
Materials to Avoid: STRONG OXIDIZING AGENTS, ACIDS, ACID ANHYDRIDES.
Hazardous Decomposition Products: CO, CO2, NITROGEN OXIDES, HYDROGEN CYANIDE, AMMONIA.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/K

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISSOLVE/MIX MATERIAL W/A COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN AFTERBURNER & SCRUBBER IAW/FEDERAL, STATE & LOCAL REGULATIONS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media